Tuesday, 5 April 2011

Modifying Deploymentmonitor.hta

In a previous post I mentioned a utility from the Microsoft Deployment Guys which allows you to monitor how your Litetouch build is progressing. In this post I am going to show how you can modify the utility to make it a little more appropriate to your own needs.


The utility itself is a HTA file which can be edited in a text editor, my editor or preference is notepad++ as it supports several different languages and will indent and colour code languages it understands as necessary to make things easier to follow.


Onto the file itself:


Lets start early on at line 7


MINIMIZEBUTTON="NO"


for some reason the Deployment guys didn't feel the need to minimize the app to the taskbar, however in the world of education we are often doing at least three things at once and to keep the screen as uncluttered as possible you can edit the line to


MINIMIZEBUTTON="YES"


and instantly you have the option to put things out of the way.


If you are using this in a fixed location you may want to prepopulate the location for the script to check for log files, this can be done by editing line 278 from

<input id="lblEventShare" type="text" name="lblEventShare" />&nbsp;&nbsp;&nbsp;&nbsp;

to

<input id="lblEventShare" type="text" name="lblEventShare" value="\\servername\Share$" />&nbsp;&nbsp;&nbsp;&nbsp;



To automatically check the autorefresh box when starting the app change line 292 from


<input id="chkAutoRefresh" name="chkAutoRefresh"type="checkbox" />

to


<input id="chkAutoRefresh" name="chkAutoRefresh"type="checkbox" checked/>

You will still need to click the refresh button once to start the process.


To change the frequency that the app automatically checks for updates edit line 203


iTimerID = window.setInterval("Refresh", 120000)

You will also want to edit line 292 to reflect the changed time you have set.


&nbsp;Auto-refresh every 2 minutes (press &#39;Refresh Display&#39; to start)every 2 minutes (press &#39;Refresh Display&#39; to start)





Hopefully these changes will make this great utility more useful in your deployment efforts.

Import drivers into MDT maintaining folder structure

I recently got an email from Johan Arwidmark's mailing list at Truesec, this mail contained a powershell script to import drivers into MDT whilst maintaining the folder structure, this will allow multiple driver imports for a range of hardware without dumping all of the drivers in on huge lump in the 'Out Of Box Drivers' folder.


The Drivers folder layout will follow the format as follows

Drivers\
     |------OS 1\
     |          |--------->Manufacturer1\
     |          |                   |----------->Model1\
     |          |                   |----------->Model2\
     |          |--------->Manufacturer2\
     |                              |----------->Model1\
     |                              |----------->Model2\
     |------OS 2\
                |--------->Manufacturer1\
                |                   |----------->Model1\
                |                   |----------->Model2\
                |--------->Manufacturer2\
                                   |----------->Model1\
                                   |----------->Model2\



     
You will need to edit the first three lines of this script to match your environment, otherwise it should be good to go.


$DriverStore = "C:\Drivers"
$MDTDSRoot = "C:\MDTBuildLab"
$PSDriveName = "DS001"

Add-PSSnapIn Microsoft.BDD.PSSnapIn
New-PSDrive -Name "$PSDriveName" -PSProvider MDTProvider -Root $MDTDSRoot
# Proces each of the operating systems folders
Get-ChildItem "$DriverStore" | foreach {

    # Display the folder we are processing
    Write-Host "Processing $($_.FullName)" -ForeGroundColor green;Write-Host ""

    # Create the operating system folder in the MDT 2010 Deployment Workbench
    new-item -path $PSDriveName":\Out-of-Box Drivers" -enable "True" -Name "$($_.Name)" -ItemType "folder" -Verbose

    # Process each of the vendor folders
    $OSFolder = $_
    Get-ChildItem $_.FullName | foreach {
       
        # Display the folder we are processing
        Write-Host "Processing $($_.FullName)" -ForeGroundColor green;Write-Host "" 

        # Create the vendor folder in the MDT 2010 Deployment Workbench
        new-item -path $PSDriveName":\Out-of-Box Drivers\$OSFolder" -enable "True" -Name "$($_.Name)" -ItemType "folder" -Verbose
       
       # Process each of the model folders
       $VendorFolder = $_
       Get-ChildItem $_.FullName | foreach {

            # Display the folder we are processing
            Write-Host "";Write-Host "Processing $($_.FullName)" -ForeGroundColor green;Write-Host "" 
   
           # Create the model folder in the MDT 2010 Deployment Workbench
           new-item -path $PSDriveName":\Out-of-Box Drivers\$OSFolder\$VendorFolder" -enable "True" -Name "$($_.Name)" -ItemType "folder" -Verbose

           # Import the drivers into MDT 2010 Deployment Workbench
           Import-MDTDriver -Path $PSDriveName":\Out-of-Box Drivers\$OSFolder\$VendorFolder\$($_.Name)" -SourcePath "$($_.FullName)" -Verbose
          }
    } 
}

During testing of this script I encountered errors while creating folders, this error appears to be down to the code using  '-enable "True"' powershell spits this out with some ugly red lettering, I have found that by removing this part of the code the script appears to run perfectly and populate MDT as we hope.

Friday, 1 April 2011

Monitoring MDT Litetouch task sequence

When using MDT to deploy machines in school, we currently have the system set so that we enter a computer name and pick an image type then everything else is automatic, we have the machines put into the computers container in AD, this is due to the fact that we have not set MDT to automatically name and place machines yet.

If the need to rebuild a machine arises we will start off the process and leave the machine running, the task sequence will lock the workstation wherever necessary due to the system being logged on as an admin account, however the difficulty lies in knowing when the build has completed and being able to move the computer to its correct OU.

If we move the machine too soon then other scripts will run which may affect the task sequence such as the installation of antivirus which may quarantine needed files. If we fail to move the machine then it will be built and on the domain but will have no curriculum software,

MDT has a useful feature which can write log files as each stage of the task sequence is completed, using this you can monitor how far along a machine is.

To set this up:

  1. Create a share on a server, you can use either an open or hidden share.
  2. Edit the Default section in your deployment share customsettings.ini to include the following line.

    EventShare=\\Servername_or_IP\Sharename$

  3. Update your deployment share.

Any new builds you start will write log files to the shared folder, initially the log will have a MININT name but as soon as the computer is given a correct name the logs will use this.


To make it easier to monitor what is going on in these logs the Deployment guys have written a utility to display the current info in an easier to read format, this can be downloaded from the original post.

Essentially the utility is a HTA which will monitor a given folder which you set, the optional refresh period of two minutes will allow you to keep a background eye on the build process.

To use the utility, download and extract the zip file from their page to a relevant location, double click on the DeploymentMonitor.hta file. Enter the path to the share you created and click refresh. The utility will return the contents of the folder, if you wish to have the utility update every two minutes tick the checkbox and then click refresh.


This utility will not clear out the folder so you will need to perform some housekeeping from time to time depending on how many builds you perform as the folder will gradually fill up with old info.


Disclaimer::
As with all of the Deployment/Scripting Guys utils they are provided with no warranties or guarantees of any kind, their use is entirely at your own risk.

Saturday, 26 March 2011

sparkeh blog: Making Installshield deployments silent

Whilst trawling through edugeek.net this morning I found this post which could be useful for anyone who wants to make an Installshield installation silent. Although I already knew about the /s switch using /r was new to me. Hopefully he will continue to post new information that I don't have the time to find out for myself.

sparkeh blog: Making Installshield deployments silent



I have posted the text below as found on the site:


"Every so often I come across something that I am astounded that I don't already know. This might be a lot of old chips to you but whilst looking for tips on deploying Installshield installers I stumbled across guidance on making the deployment silent.
As you probably know, Installershield deployments usually come as a setup.exe file. This is not always the case but then you can usually grab the setup.exe and other setup files (cab file for example) from a temp folder when you launch the installer.
If you want to make the installation silent you need to use the /s switch, however the installer will look for and answer file called setup.iss. If you are luck then your software vendor will have provided one. Not very often though in my experience.
The good news though, is that you can create one yourself by running the installation with the record switch /r. This dumps a setup.iss file in c:\windows. Move this to the same directory as the installer and you can run the installation silently (with /s) with all the options you chose in the recorded run through. Well almost ;)

There is one sting in the tale to be aware of though. Due to a forked process starting up and completing before the installation is complete, you need to add another switch (/sms) to force the process to wait until the installation is complete.
So in summary, once you have a installer with its setup.iss in place you can run 'setup.exe /s /sms'."

Thursday, 24 March 2011

Windows 7 Godmode

I thought I'd better introduce myself, I'm The IT Nut, a colleague of the Primary School Tech, and I will be dropping a few posts on here from time to time.

I'll be specialising in Powershell Tips and creating MSI packages for group policy rollout, along with links to a few projects of my own.

To start with though, I thought I begin with GodMode! I found out about this feature and thought it was rather neat.
GodMode is a hidden feature in Windows 7 as well as windows vista. By enabling this feature allows you to access all windows settings in a single place. It is a single folder that collects all of the control panel functions,interface customization,accessibility options etc..

Steps:
•Create a new folder
•Name the folder: GodMode.{ED7BA470-8E54-465E-825C-99712043E01C}
•Then open it to show the GodMode window.

GodMode enabled.

Friday, 11 March 2011

Resetting Tandberg TS800 LTO3 drive

Recently I was met with a Tandberg TS800 (820LTO) drive which had a flashing fault LED, after some searching I found the following procedure to work

Ensure that the Fault LED is flashing amber and that the Activity LED is off.


1. Press the Eject button for at least 6 seconds so that the Ready LED is flashing (Service Mode)
2. Press the Eject button once more (Activity LED Flashing)
3. Press the Eject button twice to reset the drive (You will hear the drive resetting)
3. Press Eject once more to exit service mode



If the button is not pushed for 15 seconds, the eject button reverts back to its original cartridge eject function.

Using GParted to repair NTFS partition size

While using P.I.N.G. to make a backup of a machine I chose to shrink the partition before taking an image, this was necessary as I did not have either the space or time to wait for a 320Gb image to be created over a network connection.

P.I.N.G. uses the linux utility ntfsresize to work out how small the partition can be, resizes the partition then takes an image of it. Unfortunately in this instance when finished it did not resize the partition back to full size (I am unsure if it should by default)

This left me with the situation that Windows XP thought it had a 320Gb hard drive with an 11Gb partition, being unable to save any further data to the disk meant that windows was an unhappy bunny.


In theory I could use ntfsresize from the command line to expand the partition to fill the hard drive again, however when I tried this I was getting various error messages about not being able to access the drive.

Step in GParted and the ever useful Ubuntu bootable USB Stick, simply boot into the Ubuntu system, right click the disk you need to work on and select "Resize/Move" simply reduce the size by 1 meg and click apply, then click the green tick to apply the settings, close out of GParted and rebooth the machine back into windows, you should find that the partition is correctly showing as the full size minus 1 meg.